DHW 100 | TIKI

DHW 100

A+
  • Power consumption within 24 hours
    2,225 kWh
  • AEC annual electricity consumption PPR
    464 kWh
  • Storage volume V
    97,9 l
  • Net/Gross/Weight with water
    62 / 65 /162 kg
High quality insulation
Indirect tube air heaters
Overheating protection
Air ducts
Anti-legionella function

Operation range +7°C to +35°C.

Heating of water up to 55°C.

Possibility of ventilation of space independently of the heat pump’s operation.

Technical properties

Characteristics

Declared load profile
M
Energy efficiency class
A+
Energy efficiency ƞwh
111 %
AEC annual electricity consumption PPR
464 kWh
Power consumption within 24 hours
2,225 kWh
Thermostat temperature settings
55 °C
Sound power level LWA, indoors /Sound Pressure on 1m
51 / 39,5 dB(A)
Value of smart
0
Storage volume V
97,9 l
Mixed water at 40°C V40
130 l

Technical characteristics

Heating time A15/W10-55
5h 40min
Heating time A7/W10-55
6h 50min
Energy consuption by choosen cyclus A15/W10-55
2,05 kWh
Energy consumption by chosen cycle A7/W10-55
2,35 kWh
COPDHW (A15 / W10-55) EN 16147 *
3,10
COPDHW (A7 / W10-55) EN 16147
2,63
Refrigiant
R134a (GWP 1430)
Quantity of refrigiant
0,490 kg
Working range - air temperature
+ 7 / + 35 °C
Working Air Flow
100-230 m3/h
Pressure Drop by 150m3/h (60%/80%)
70 (90) Pa

Electrical specifications

Nominal electrical power -compressor
250 W
Maximum power consumption
2350 W
Number of el.heaters x power
2 x 1000 W
Voltage/Frequecy
230/50 V/Hz
Electric protection
16 A
Degree of protection
IP24

Storage tank

Enamelled steel / Protection Mg anode
+/+
Working pressure
0,6 (6) / 0,9 (9) Mpa (bar)

Max temperature

Hot water tank heat pump
55 °C
Hot water tank electric heater
75 °C

Connection dimensions

Average thickness of insulation
50 mm
Connections to the supply network
G 1/2
Dimensions of air connections
Ø125 (150x70) /10 mm/m
Net/Gross/Weight with water
62 / 65 /162 kg

Transportation data

Packaging dimensions [WxDxH]
575x600x1510 mm

Documents