Prime CL 200
D
-
Storage volume V191,9 l
-
Daily electricity consumption Qelec_ACC22,430 kWh
-
AEC annual electricity consumption4756 kWh
-
Net/gross weight/with water72/269 kg
Technical properties
Characteristics
Declared load profile
XL
Energy efficiency class
D
Energy efficiency ƞwh
35 %
AEC annual electricity consumption
4756 kWh
Daily electricity consumption Qelec_ACC
22,430 kWh
Thermostat temperature settings
"e" / "eco"
Value of smart
0
Storage volume V
191,9 l
Mixed water at 40°C V40
266 l
Purpose
One or more connection point
+
Vertical wall mounting
+
Dimensions of connections
Average thickness of insulation
25 mm
Connections to the supply network
G1/2
Connections for heat exchanger
G 3/4
Net/gross weight/with water
72/269 kg
Technical characteristics
Working pressure
0,6 (6)/0,9 (9) MPa (bar)
Enamelled steel
+
Protective magnesium anode
+
Selection of temperature up to 65 °C
+
Heating element control lamp
+
Protection against freezing
+
Termometer
+
Degree of protection
IP 23
Heat exchanger
Surface area of the heat exchanger
0,40 m2
Exchange power in continuous mode (max. coil output)
10,55 kW
Continuous flow rate of DHW at ΔT35 °C
265 l/h
Max. pressure of the heating medium
0,6 (6) MPa (bar)
Max. input temperature
5 - 85 °C
Electrical connections
Power consumption
2000 W
Voltage 230 V ~
+
Nominal current
8,7 A
Functional characteristics
Thermal losses at 65 °C
2,80 kWh/24
Heating time from 10 to 55 °C
6h 32min
Transportation data
Packaging dimensions [WxDxH]
600x600x1610 mm