Prime CR 100
C
-
Storage volume V90,7 l
-
Daily electricity consumption Qelec_ACC12,850 kWh
-
AEC annual electricity consumption2762 kWh
-
Net/gross weight/with water38/135 kg
Technical properties
Characteristics
Declared load profile
L
Energy efficiency class
C
Energy efficiency ƞwh
37 %
AEC annual electricity consumption
2762 kWh
Daily electricity consumption Qelec_ACC
12,850 kWh
Thermostat temperature settings
"e" / "eco"
Value of smart
0
Storage volume V
90,7 l
Mixed water at 40°C V40
130 l
Purpose
One or more connection point
+
Vertical wall mounting
+
Dimensions of connections
Average thickness of insulation
23 mm
Connections to the supply network
G1/2
Connections for heat exchanger
G 3/4
Net/gross weight/with water
38/135 kg
Technical characteristics
Working pressure
0,6 (6)/0,9 (9) MPa (bar)
Enamelled steel
+
Protective magnesium anode
+
Selection of temperature up to 65 °C
+
Heating element control lamp
+
Protection against freezing
+
Termometer
+
Degree of protection
IP 23
Heat exchanger
Surface area of the heat exchanger
0,40 m2
Exchange power in continuous mode (max. coil output)
10,55 kW
Continuous flow rate of DHW at ΔT35 °C
265 l/h
Max. pressure of the heating medium
0,6 (6) MPa (bar)
Max. input temperature
5 - 85 °C
Electrical connections
Power consumption
2000 W
Voltage 230 V ~
+
Nominal current
8,7 A
Functional characteristics
Thermal losses at 65 °C
1,72 kWh/24
Heating time from 10 to 55 °C
3h 10min
Transportation data
Packaging dimensions [WxDxH]
488x498x960 mm